Page view 11
Figure 8. Wire gauge versus
maximum wire run (with a
maximum loop resistance of
0.07 ohms) for less than 0.2 dB
response error.
NOTE: “Loop resistance” is the
DC resistance measured at one
end of a loudspeaker cable, with
the other ends shorted together.
CONNECTIONS
REVEL ULTIMA STUDIO loudspeakers can be connected to
your audio system in three different ways: single-wired, bi-wired or
bi-amplified. Please read the following three sections before pro-
ceeding with the actual connections. Also, be sure to observe the
following points:
Use high-quality speaker cable with a maximum total loop resis-
tance (for each wire run) of 0.07 ohms or less. Use the chart in
Figure 8 below to determine the maximum wire gauge.
NOTE: Bi-wiring does not reduce the effective loop resistance
of individual runs. Higher loop resistance will result in mis-
termination of the filter networks, and serious degradation
of sound quality. Use high-quality connectors on the speaker
cables. Consult your Revel dealer as to specific recommenda-
tions for your application.
Turn off all audio system power before making any connections.
Read the owner’s manuals that were included with your audio
components to confirm their connection procedures.
Verify correct polarities (i.e., + to + and to ) when making
connections. Failure to do so will cause poor imaging and
diminished bass response.
For bi-wired or bi-amplified applications, remove the shorting
straps on the rear of each REVEL ULTIMA STUDIO loud-
speaker (refer to Figures 9, 10, and 11 on the next three pages).
REVEL ULTIMA STUDIO
Owner’s Manual
12
WIRE GAUGE (AWG) LENGTH (FEET)LENGTH (METERS)
68727
76921
85818
94313
10 34 10
11 27 8
12 22 7
13 17 5
14 14 4
15 11 3
16 9 3
17 7 2
18 5 2
Page view 11